Moteur de recherche de fiches techniques de composants électroniques
Selected language     French  ▼

Delete All
ON OFF
ALLDATASHEET.FR

X  

Preview PDF Download HTML

G-MRCO-015 Datasheet(Fiches technique) 2 Page - TE Connectivity Ltd

Numéro de pièce G-MRCO-015
Description  AMR Sensor with 180° period
Télécharger  6 Pages
Scroll/Zoom Zoom In 100% Zoom Out
Fabricant  TEC [TE Connectivity Ltd]
Site Internet  http://www.te.com/usa-en/home.html
Logo TEC - TE Connectivity Ltd

G-MRCO-015 Datasheet(HTML) 2 Page - TE Connectivity Ltd

  G-MRCO-015 Datenblatt HTML 1Page - TE Connectivity Ltd G-MRCO-015 Datasheet HTML 2Page - TE Connectivity Ltd G-MRCO-015 Datenblatt HTML 3Page - TE Connectivity Ltd G-MRCO-015 Datenblatt HTML 4Page - TE Connectivity Ltd G-MRCO-015 Datenblatt HTML 5Page - TE Connectivity Ltd G-MRCO-015 Datenblatt HTML 6Page - TE Connectivity Ltd  
Zoom Inzoom in Zoom Outzoom out
 2 / 6 page
background image
KMT32B
Magnetic Angle Sensor
SENSOR SOLUTIONS /// KMT32B Rev 6
1/2016
Page 2
APPLICATIONS
Absolute and incremental angle measurement
Automotive (steering angle, torque)
Robotics
Camera positioning
Potentiometer replacement
Position measurement in medical applications
Motor motion control
CHARACTERISTIC VALUES
Parameter
Symbol
Condition
Min
Typ
Max
Unit
A. Operating Limits
Max. supply voltage
Vcc,max
10
V
Max. current (single bridge)
Icc,max
4
mA
Operating temperature
Top
-40
+150
C
Storage temperature
Tst
-40
+150
C
B. Sensor Specifications (T=25 °C)
Supply voltage
Vcc
5
V
Resistance (single bridge)
Rb
2400
3000
3600
Output signal amplitude
VPEAK
Condition A, B
9
11
13
mV/V
Offset voltage
VOFF
Condition A, B
-1
0
+1
mV/V
Angular inaccuracy

Condition A, B
0.05
0.2
deg
Angular hysteresis

H
Condition A, B
0.1
deg
C. Sensor Specifications
TC of amplitude
TCSV
Condition A, C
-0.35
%/K
TC of resistance
TCBR
Condition A, C
+0.35
%/K
TC of offset
TCVoff
Condition A, C
-4
0
+4
µV/V/K
Stress above one or more of the limiting values may cause permanent damage to the device. Exposure to limiting
values for extended periods may affect device reliability.
MEASUREMENT CONDITIONS
Parameter
Symbol
Unit
Condition
Condition A: Set Up Conditions
Ambient temperature
T
°C
T = 25 °C (unless otherwise noted)
Supply voltage
Vcc
V
Vcc = 5 V
Applied magnetic field
H
kA/m
H = 25 kA/m


Html Pages

1  2  3  4  5  6 


Datasheet Download

Go To PDF Page


Lien URL



Privacy Policy
ALLDATASHEET.FR
AllDATASHEET vous a-t-il été utile ?   [ DONATE ]  

À propos de Alldatasheet   |   Publicit   |   Contactez-nous   |   Politique de confidentialit   |   Echange de liens   |   Manufacturer List
All Rights Reserved© Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn