11 / 26 page CS10.241, CS10.241-S1 C-Line 24V, 10A, SINGLE PHASE INPUT 9. LIFETIME EXPECTANCY AND MTBF AC 100V AC 120V AC 230V Lifetime expectancy*) 93 000h 99 000h 118 000h at 24V, 5A and 40°C 264 000h*) 281 000h*) 334 000h*) at 24V, 5A and 25°C 38 000h 50 000h 82 000h at 24V, 10A and 40°C 107 000h 141 000h*) 233 000h*) at 24V, 10A and 25°C 27 000h 34 000h 53 000h at 24V, 12A and 40°C 75 000h 97 000h 149 000h*) at 24V, 12A and 25°C MTBF**) SN 29500, IEC 61709 612 000h 638 000h 821 000h at 24V, 10A and 40°C 520 000h 542 000h 698 000h at 24V, 12A and 40°C 1 019 000h 1 058 000h 1 393 000h at 24V, 10A and 25°C MTBF**) MIL HDBK 217F 456 000h 447 000h 472 000h at 24V, 10A and 40°C; Ground Benign GB40 410 000h 402 000h 425 000h at 24V, 12A and 40°C; Ground Benign GB40 632 000h 628 000h 653 000h at 24V, 10A and 25°C; Ground Bening GB25 *) The Lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and is calculated according to the capacitor’s manufacturer specification. The manufacturer of the electrolytic capacitors only guarantees a maximum life of up to 15 years (131 400h). Any number exceeding this value is a calculated theoretical lifetime which can be used to compare devices. **) MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product. The MTBF figure is a statistical representation of the likelihood of a device to fail. A MTBF figure of e.g. 1 000 000h means that statistically one unit will fail every 100 hours if 10 000 units are installed in the field. However, it can not be determined if the failed unit has been running for 50 000h or only for 100h. 10. FUNCTIONAL DIAGRAM Fig. 10-1 Functional diagram + + - - V OUT Input Fuse & Input Filter Output Voltage Regulator Power Converter Output Filter DC ok L N Output Over- Voltage Protection Input Rectifier & Inrush Limiter 115/230V Auto Select Jul. 2015 / Rev. 2.0 DS-CS10.241-EN All parameters are specified at 24V, 10A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 11/26 |
Numéro de pièce similaire - CS10.241 |
|
Description similaire - CS10.241 |
|
|
Lien URL |
Politique de confidentialité |
ALLDATASHEET.FR |
ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |