2 / 4 page Solid State Remote Power Controller E-1048-S6... www.e-t-a.de Solid State Remote Power Controller E-1048-S6... 1646 2 5 10 20 1000 100 10 1 0.1 30 I (A) current limitation I N 20 40 1000 100 10 1 0.1 60 I (A)) 80 I N current limitation 0.5 A and 1 A 2 A and 4 A Technical description Status indication Dimensions Connection diagram Typical time/current characteristics (TA = 25 °C) 7 3 2 5 control and monitoring electronics F + F - control circuit red green Q -U S 4 6 1 +U S E-1048-S600 IN+ IN- fault output Fault indication output (opto coupler) LED green red non-conductive, no duty conductive, normal duty overload or short circuit at the output (and with option wire break indication in ON condition) wire break, in the OFF position Status indication At the appropriate input level (>8.5 V), the opto decoupled input in the SSRPC will switch on a power transistor to connect the load to the plus pole of the load circuit supply (US). The transistor will switch off when - the control voltage (UE) is removed - there is a short-circuit/overload in the load circuit. Status indication is provided by two LEDs (red and green). Thermal-magnetic style overload protection occurs at approx. 1.5 times rated current. See time/current characteristic curves. The SSRPC is fitted with blade terminals DIN 46244-A6.3-0.8 and is suitable for plug-in mounting with various E-T-A sockets (see Accessories). Control circuit ON condition: If a voltage higher than 8.5 V is applied to the input terminals (-IN, +IN), the control current (from the PLC) will flow through the opto coupler. The output transistor will be conductive, the green LED will be lighted. OFF condition: A control voltage lower than 5 V will switch the output transistor off. Load circuit The load circuit switches depending on the control signal (“0” or “1”). It is electronically monitored for faults. In the event of a short-circuit the circuit is disconnected after max. 250 µs whilst upon inadmissible overload it is disconnected according to the time/current curves shown. Fault indication output The fault indication circuit (F+, F-) is opto decoupled from the load and control circuit. In the OFF condition, this circuit will provide wire break indication, with the transistor output being open. In the ON condition, the circuit will provide short-circuit and overload monitoring and indication. Visual fault indication by red LED. blade terminals DIN 46244-6.3-0.8 60 50 6x6.8=40.8 6.8 reverse plug-in protection LED green LED red 1 4 6 3 7 5 2 6x.267=1.60 .267 1.97 2.36 This is a metric design and millimeter dimensions take precedence ( mm ) inch |
Numéro de pièce similaire - E-1048-S600DC24V1.0A |
|
Description similaire - E-1048-S600DC24V1.0A |
|
|
Lien URL |
Politique de confidentialité |
ALLDATASHEET.FR |
ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |