Moteur de recherche de fiches techniques de composants électroniques |
|
DLE Fiches technique(PDF) 1 Page - XP Power Limited |
|
DLE Fiches technique(HTML) 1 Page - XP Power Limited |
1 / 2 page Specification 15 Watts • AC Input LED Driver • Constant Voltage & Current Versions • High Power Factor • High Efficiency • Water Proof to IP67 • Class 2 • 3 Year Warranty DLE Series Input Input Voltage • 90-264 VAC, see derating curve Input Frequency • 47-63 Hz Input Current • 0.25 A at 115 VAC, 0.1 A at 230 VAC Inrush Current • 15 A at 230 VAC, cold start +25 °C Power Factor • >0.83 at 230 VAC, full load No Load Input Power • <0.5 W max at 230 VAC Input Protection • Internal T1.0A/250V fuse fitted in line Output Output Voltage • See table Minimum Load • No min load required Start Up Delay • 500 ms max at 115 VAC Hold Up Time • No hold up for -A versions, 6ms min for -V versions Line Regulation • ±0.5% Load Regulation • ±1.0% in constant voltage mode, ±5.0% in constant current mode Turn On Overshoot • 5% max Transient Response • 5% max deviation, recovery to within 1% in 10 ms for a 50% load change Ripple & Noise • 1% max mV pk-pk, for - V versions (see note 2) Overload Protection • 130-160% for -V versions, auto recovery Short Circuit Protection • Trip and restart (hiccup mode) Temperature • 0.04%/°C Coefficient xppower.com General Efficiency • See table Isolation • 3750 VAC Input to Output Switching Frequency • 100 kHz typical MTBF • >200 kHrs to MIL-HDBK-217F at 25 °C, GB Environmental Operating Temperature • -20 °C to +70 °C (see derating curve) Operating Humidity • 5-100% RH, non-condensing Storage Temperature • -40 °C to +80 °C Operating Altitude • 3000 m Vibration • 10-500 Hz, 2 g, 10 mins/cycle, 6 cycles in each of 3 axes EMC & Safety Emissions • EN55015, class B conducted and radiated Harmonic Currents • EN61000-3-2, class C Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, 8 kV air and 4 kV contact, Perf Criteria A Radiated Immunity • EN61000-4-3, level 2 Perf Criteria A EFT/Burst • EN61000-4-4, level 2 Perf Criteria A Surge • EN61000-4-5, installation class 3, Perf Criteria B Conducted Immunity • EN61000-4-6, level 2 Perf Criteria A Dips & Interruptions • EN61000-4-11, 100% 10 ms, 30% 200 ms, Perf Criteria B, B Safety Approvals • EN61347, UL8750, CE Mark |
Numéro de pièce similaire - DLE |
|
Description similaire - DLE |
|
|
Lien URL |
Politique de confidentialité |
ALLDATASHEET.FR |
ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |