2 / 4 page www.murata-ps.com cPCI-A-3U-200C Series 200W 3Ux8HP AC/DC CompactPCI™ cPCI-A-3U-200C.A01 Page 2 of 4 STATUS & CONTROL SIGNALS & INDICATORS Name Description Enable (EN#) Contact closure to external ground to start unit. On shortest pin (last make, first break). Output Inhibit (INH#) TTL –compatible signal inhibited with GND or TTL “0”. Output Fault (FAL#) TTL compatible signal ,open collector active low signal .Indicates one or more outputs below 90% of specified rate. Remote Sense (RS+, RS-) Available on V1 & V2. Maximum voltage compensation for cable losses 200mV. Thermal Warning (DEG#) Open collector active low 10ºC before power supply shut down. Front Panel Power Indicator LED A single bi-color indicator LED Green LED - indicates output in range Red LED - indicates one or more outputs below 90% of specified range. GENERAL CHARACTERISTICS Parameter Conditions Min Typ Max Units Efficiency 230Vac, full load 80 % 120Vac, full load 76 Switching Frequency Main Converter 68 kHz MTBF Calculated per Bellcore standard B332 Gb 30ºC 300 khrs Weight Unpackaged 800 g PROTECTION Parameter Conditions/Response Inception Units Min Typ Max Inrush Current Limit 230VAC 50 A rms Input Protection Internal line fuse 6.3 A rms Over-voltage Protection V1, V2, & V3 with latched shutdown 110 130 %V nom Parameter Conditions/Response Output Overload Protection Outputs are individually protected against overloads and indefinite short circuit with automatic recovery upon removal of the fault condition. Hot-Swap Capability Protected by internal ORing diodes Output Fault Isolation Output isolation devices are present in all outputs to isolate faults within a failed power supply. Thermal Shutdown Automatic recovery upon restoration to operational temperatures ENVIRONMENTAL CHARACTERISTICS Parameter Conditions Min Typ Max Units Ambient Operating Temperature Full load with 250LFM forced air and derating linearly above 55°C to 70°C, by 2.5% per °C -5 55 ºC Ambient Storage Temperature -40 85 ºC Operating Humidity Non-condensing 95 % Storage Humidity Non-condensing 95 % Altitude Operating 6000 ft Storage 40000 ft |
Numéro de pièce similaire - TPS_CPCI-A-3U-200C |
|
Description similaire - TPS_CPCI-A-3U-200C |
|
|
Lien URL |
Politique de confidentialité |
ALLDATASHEET.FR |
ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |