2151 Fiches technique(PDF) 2 Page - Systemsensor advanced ideas.

No de pièce 2151
Description  Low-Profile Plug-in Smoke Detectors
Download  2 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricant  SYSTEMSENSOR [Systemsensor advanced ideas.]
Site Internet  http://www.systemsensor.com
Logo SYSTEMSENSOR - Systemsensor advanced ideas.

2151 Fiches technique(HTML) 2 Page - Systemsensor advanced ideas.

  2151 Datasheet HTML 1Page - Systemsensor advanced ideas. 2151 Datasheet HTML 2Page - Systemsensor advanced ideas.  
Zoom Inzoom in Zoom Outzoom out
 2 / 2 page
background image
3825OhioAvenue•St.Charles,IL60174
Phone:800-SENSOR2•Fax:630-377-6495
©2007 System Sensor.
Product specifications subject to change without notice. Visit systemsensor.com for
current product information, including the latest version of this data sheet.
A05-0182-012•9/08•#1799
100 Series Plug-in Smoke Detector Specifications
Operating Voltage/Alarm Current
See Adapter Base Selection Guide following
Standby Current
120µA Standby (when mounted in a B110LP base)
Sensitivity
1–3.18%/ft.
Height
2.0˝ in B401
Diameter
4.1˝ installed in B401; 6.2˝ installed in B110LP
Shipping Weight
5.2 oz
Construction
Flame retardant thermoplastic
Temperature
Photo:32°Fto120°F(0°to49°C);Photo/thermal:32°Fto100°F(0°to38°C)
UL Listed Velocity Range
Photo:0–3000fpm(0–15.2m/s)
Humidity Range
10% – 93% RH non-condensing
Smoke Detector Spacing
On smooth ceilings (as defined in NFPA 72), spacing of 30 feet (900 sq. ft.) may be used as a guide. Other spacing may
be used depending on ceiling height, high air movements, and other conditions or response requirements.
Adapter Base Selection Guide
Base Model Number
Loop Type
Current Limit Resistor
Contact Type
Nominal Voltage
Current Draw on
Alarm (mA)
B110LP/B401B**
2-wire*
No
12/24VDC
10–130
B110RLP/B401BR**
2-wire*
Yes
24VDC
10–62
B112LP/B402B**
4-wire
Yes
Form A&C
24VDC
17–36
B114LP/B404B**
4-wire
Yes
Form A&C + A Supervisory
120VAC
75 mA AC Max
B116LP/B406B**
2-wire*
No
Form C
24VDC
20–100
B401††
2-wire*
No
12/24VDC
10–130
*Functionalitycontingentonpanelcompatibility†Mustbelimitedbycontrolpanel††Flangelessbase
**The400Series6-inchbases,B401B,B401BR,B402B,B404B,andB406B,havebeenmadecompatiblewiththe
new 100 Series for retrofit applications only. When using these 400 Series bases, use the F110 flange.
Relay Contact Ratings:
Resistive or Inductive (60% power factor) load.
Form A:
2.0Aat30VAC/DC
Form C:
0.6A at 110VDC, 2.0A at 30VDC
1.0A at 125VAC, 2.0A at 30VAC
Ordering Information
Part No.
Description
2151
Low-profile photoelectric detector. Must be mounted to one of the B100 Series or B400 Series bases listed in the Adapter Base Selection Guide.
2151T
Low-profile photoelectric detector with thermal. Must be mounted to one of the B100 Series or B400 Series bases listed in the Adapter Base
Selection Guide.
Accessories
F110
Retrofit replacement flange for B400 Series flanged bases.
RA400Z
Remote annunciator for 2 or 4 wire systems, 3–32V. Fits standard single gang electrical box.
B401BH-2
Sounder base. Requires an external 24 VDC power supply. Mounts to 4˝ square electrical box (1½˝ minimum depth, 21⁄8˝ recommended).
SENS-RDR
Hand-held sensitivity reader.
SMK400
Surface mounting kit provides for entry of surface wiring conduit. For use with B401 or B401R mounting bases only.
EOLR-1
Endoflinerelayforpowersupervision,12/24VDCsystems.
M02-04-01
Test magnet.
M02-09-00
Test magnet with 32˝ telescoping handle.
XR-2B
Detectorremovaltool.Allowsinstallationand/orremovalof100SeriesdetectorheadsfrombaseinhighceilinginstallationswhenusedwithXP-4.
XP-4
Extension pole for XR-2B. Comes in three 5 ft. sections.
C58-227-01
Replacement dust cover for 100 Series smoke detectors.
RMK400
Recessed mounting kit (B401 sold separately).
Junction Box Selection Guide*
Base Model Number
Single Gang
3½˝ Octagon
4˝ Octagon
4˝ Square
50 mm
60 mm
75 mm
B401
No
No
No
No
Yes
Yes
No
B110LP/RLP
Yes
Yes
Yes
Yes
No
No
No
B112LP/B116LP
Yes
Yes
Yes
Yes
Yes
Yes
Yes
B114LP
No
No
Yes
Yes
No
No
No
*Boxdepthcontingentonbaseandwiresize.RefertoNationalElectricalCodeorlocalapplicablecodesforappropriaterecommendations.


Html Pages

1  2 


Fiches technique Télécharger

Go To PDF Page

Numéro de composants électroniques

No de pièceDescriptionHtml ViewFabricant
7251 Low-Profile Plug-in Intelligent Laser Smoke Detector 1  2  Systemsensor advanced ideas.
B210LP Low-Profile Intelligent Combination Smoke Detector 1  2  Systemsensor advanced ideas.
72247 For Duct Smoke Detectors 1  2  List of Unclassifed Manufacturers
2W-B Photoelectric Smoke Detectors 1  2  Systemsensor advanced ideas.
1451A Plug-in Smoke Detector 1  2  3  4  Systemsensor advanced ideas.
2WTA-B Smoke Detectors with Sounder and Relay Option 1  2  Systemsensor advanced ideas.
RT9801A User Programmable Micro-Power Voltage Detectors 1  2  3  4  5  More Richtek Technology Corporation
PDU-G101A UV Enhanced GaN Detectors 1  Advanced Photonix, Inc.

Lien URL




Politique de confidentialité
ALLDATASHEET.FR
ALLDATASHEET vous a-t-il été utile ?  [ DONATE ] 

À propos de Alldatasheet   |   Publicité   |   Contactez-nous   |   Politique de confidentialité   |   Echange de liens   |   Fabricants
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn