E-1072-220-DC24V-1A Fiches technique(PDF) 1 Page - ETAL Group |
|
E-1072-220-DC24V-1A Fiches technique(HTML) 1 Page - ETAL Group |
1 / 4 page www.e-t-a.de Solid State Remote Power Controller E-1072-2... 1646 1 5 E-1072-220 Description The E-T-A Solid State Remote Power Controller E-1072-2.. complies with the EC Machinery Directive 98/37/EG and meets the requirements of EN60204 part 1 “Electrical equipment of machinery, safety of machinery” in ungrounded DC 24 V supply systems (“IT systems”). The E-1072-2.. is a double pole electronic switching amplifier for magnetic valves (hydraulic and pneumatic mechanisms), magnetic brakes and magnetic couplings with rated voltage DC 24 V and a max. current rating of 1 A or 2 A. It combines true circuit breaker characteristics with additional diagnostic functions. Why use the E-1072-2.. Features l Voltage rating DC 24 V (19.2...36 V) l Current rating IN max. 1 A or 2 A (min. load current 30 mA) l Activates and monitors DC 24 V magnetic valves l PLC controllable 2 pole remote power controller with physical isolation of control input - Switching output with integral current limitation to 2 x IN - Disconnection of load in the event of short circuit or overload, followed by double pole physical isolation of load - Permanent wire break monitoring of load circuit - Group fault signalisation via relay contact “Err1” - Additional signal contact “Err2” when integral circuit breaker has tripped due to short circuit or overload in the load circuit - LED displays: LED green: OK LED red: Error LED yellow In/Ctrl (control current indication) - Integral reverse polarity protection and overload protection for control and load circuit - No back-up fuse required due to integral fail-safe element - Track-mountable, width 22.5 mm Additional feature E-1072-210 - additional “status indication” relay output to facilitate confirmation to a PLC, for example, of activation and a load current > 30 mA. Additional feature E-1072-220 (see fig. “inrush current curve magnetic valves”) - Analogue output 4-20 mA proportional to load current enables permanent monitoring of magnetic valve circuits as well as recording of the load current via ET200 sub-assemblies or field bus modules (with analogue input). In addition it is possible to check the inrush current characteristic curve of a magnetic valve to determine whether the armature of the valve has moved or is stuck. Voltage rating UN DC 24 V Operating voltage US DC 19.2...36 V Current rating IN max. 1 A or 2 A Current consumption I0 typically 25 mA (UContr = “0”) Power loss Pmax (IN= 1 A) typically 1.6 W Residual ripple for all voltages max. 5 % (3 phase bridge) Reverse polarity protection US integral -> fault release, LEDs not lighting Caution: Ensure free travel of actuator button. Insulation voltage AC 500 V (control circuit, load circuit, fault indication “Err1” and “Err2”) indication “BM” Load Circuit Load output two pole switching output (minus and (term. 31-term. 32) plus switching), MOS transistors Max. load data DC 24 V/1 A or 2 A (no derating over the entire temperature range!) Min. load data DC 24 V / 50 mA (wire break threshold 30 mA) Voltage drop at IN (with IN=1 A) typically 0.8 V Switching times (ton/toff) typically 1 ms (resistive load) Overload disconnection approx 1.15 x IN Trip time (Iload = 1.5 x IN) typically 1 s Short-circuit current IK typically 2 x IN current limitaton Trip time (upon IK) typically 300 ms at IN = 1 A, 100 ms at IN = 2 A, 2-pole isolation of load circuit after approx. 20 ms –> RED LED indicates, fault indication F “Err1” and “Err2” Wire break monitoring with the load switched on or off; RED LED “Error” lighted, group fault signalisation “Err1” (UContr= “0”) wire break threshold Rload > 30 kΩ (UContr= “1”) minimum current Iload < 30 mA Supervision of load circuit with the load switched on, the load current is monitored via the two switching outputs GREEN LED indicates (OK signal), Iload > 30 mA Leakage current (UContr = “0”) typically 1 mA Free-wheeling circuitry integral Load current measurement no isolation of load circuit required as a (term. 33: +shunt/ IN = 1 A: 0.2 Ω/1 %, IN = 2 A: 0.1 Ω/1 % term. 34: -shunt) measuring shunt is integral with the device. Measurement by voltmeter terminal 33 - terminal 34 (200 mV = IN) Isolation of load circuit 2-pole by relay contacts - by manual release of RED button - approx. 20 ms after electronic tripping due to overload or short circuit (“OFF”) l for double pole switching of actuators (magnetic valves, magnetic brakes) in machinery and equipment l for monitoring the electronic function of the loads and signal to the PLC l for preventing a voltage dip of the DC 24 V output voltage in a switch-mode power supply, in the event of a short circuit, as a true 2 pole, remotely controllable electronic circuit breaker l for protecting the cables of the load circuit l for status signalling and for visually indicating load circuit faults (LEDs or RED trip button) via potential-free signal contacts l for double-pole physical isolation of the load circuit – manually or electrically in the event of a failure (short circuit/overload) Technical Data (T U = 25 °C, US = DC 24 V) (TU = ambient temperature at UN) |
Numéro de pièce similaire - E-1072-220-DC24V-1A |
|
Description similaire - E-1072-220-DC24V-1A |
|
|
Lien URL |
Politique de confidentialité |
ALLDATASHEET.FR |
ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |