8 / 14 page Typical Applications (Continued) Fahrenheit Thermometer DS005698-24 *To calibrate adjust R2 for 2.554V across LM336. Adjust R1 for correct output. THERMOCOUPLE COLD JUNCTION COMPENSATION Compensation for Grounded Thermocouple DS005698-6 *Select R3 for proper thermocouple type THERMO- R3 SEEBECK COUPLE (±1%) COEFFICIENT J 377 Ω 52.3 µV/˚C T 308 Ω 42.8 µV/˚C K 293 Ω 40.8 µV/˚C S 45.8 Ω 6.4 µV/˚C Adjustments: Compensates for both sensor and resistor tolerances 1. Short LM329B 2. Adjust R1 for Seebeck Coefficient times ambient temperature (in degrees K) across R3. 3. Short LM335 and adjust R2 for voltage across R3 corresponding to thermocouple type J 14.32 mV K 11.17 mV T 11.79 mV S 1.768 mV www.national.com 8 |
Numéro de pièce similaire - LM335Z |
|
Description similaire - LM335Z |
|
|
Lien URL |
Politique de confidentialité |
ALLDATASHEET.FR |
ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |