Moteur de recherche de fiches techniques de composants électroniques |
|
7-1414967-8 Fiches technique(PDF) 1 Page - Tyco Electronics |
|
7-1414967-8 Fiches technique(HTML) 1 Page - Tyco Electronics |
1 / 5 page 06-2011, Rev. 0611 www.te.com © 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company. Datasheets and product specification ac- cording to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Datasheets, product data, ‘Definitions’ sec- tion, application notes and all specifications are subject to change. 1 n Small power relay n Limiting continuous current 30A n Minimal weight n Low noise operation n Wave (THT) and reflow (THR/pin-in-paste) solderable versions n For twin version refer to Double Micro Relay K Typical applications Car alarm, door control, door lock, hazard warning signal, heated front/rear screen, immobilizer, lamps front/rear/fog light, interior lights, seat control, sun roof, turn signal, window lifter, wiper control. Micro Relay K (THT – THR) Automotive Relays PCB Single Relays Contact Data Typical applications Resistive/inductive load Wiper load Lamp load5) V23086-*100*-A403 V23086-*1*02-A803 V23086-***21-A502 Contact arrangement 1 form C, 1 CO 1 form C, 1 CO 1 form A, 1 NO Rated voltage 10/12VDC 10/12VDC 10/12VDC NO/NC NO/NC Rated current 30/25A 30/25A 30A Limiting continuous current 23°C 30/25A 30/25A 30A 85°C 20/15A 20/15A 20A Limiting making current 40A1) 40A1) 100A2) Limiting breaking current 30A 30A 30A Contact material AgSnO2 Min. recommended contact load 1A at 5VDC3) Initial voltage drop at 10A, typ./max. 30/300mV Operate/release time typ. 3/1.5ms4) Electrical enduranc cyclic temperature -40°C, +25°C, +85°C form C contact (CO) at 14VDC motor reverse blocked, wiper, 25A, 0.77mH 25A make/5A break, >1x105 ops. generator peak, 20A on NC,1mH >1x106 ops. form A contact (NO) at 14VDC resistive 20A lamp 100A inrush, >3x105 ops. 10A steady state >1x105 ops.5) Mechanical endurance >5x106 ops. Max. DC load breaking capacity Load limit curve 1: arc extinguishes, during transit time (changeover contact). Load limit curve 2: safe shutdown, no stationary arc (make contact). Load limit curves measured with low inductive resistors verified for 1000 switching events. 1) The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5VDC for 12VDC load voltages. For a load current duration of maximum 3s for a make/break ratio of 1:10. 2) Corresponds to the peak inrush current on initial actuation (cold filament). 3) See chapter Diagnostics of Relays in our Application Notes or consult the internet at http://relays.te.com/appnotes/ 4) Measured at nominal voltage without coil suppression unit. A low resistive suppression device in parallel to the relay coil increases the release time and reducesthe lifetime caused by increased erosion and/or higher risk of contact tack welding. 5) Be aware of using right polarity, see Terminal Assignment. Wrong polarity will reduce endurance. 086C/R1_fcw1b |
Numéro de pièce similaire - 7-1414967-8 |
|
Description similaire - 7-1414967-8 |
|
|
Lien URL |
Politique de confidentialité |
ALLDATASHEET.FR |
ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |