9 / 16 page AD676 REV. A –9– CONTINUOUS CONVERSION For maximum throughput rate, the AD676 can be operated in a continuous convert mode (see Figure 2b). This is accomplished by utilizing the fact that SAMPLE will no longer be ignored af- ter BUSY goes LOW, so an acquisition may be initiated even during the HIGH time of the 17th CLK pulse for maximum throughput rate while enabling full settling of the sample/hold circuitry. If SAMPLE is already HIGH when BUSY goes LOW at the end of a conversion, then an acquisition is immediately initiated and tS and tC start from that time. Data from the previ- ous conversion may be latched up to tSD before BUSY goes LOW or tOD after the rising edge of the 17th clock pulse. How- ever, it is preferred that latching occur on or after the falling edge of BUSY. Care must he taken to adhere to the minimum/maximum timing requirements in order to preserve conversion accuracy. GENERAL CONVERSION GUIDELINES During signal acquisition and conversion, care should be taken with the logic inputs to avoid digital feedthrough noise. It is pos- sible to run CLK continuously, even during the sample period. However, CLK edges during the sampling period, and especially when SAMPLE goes LOW, may inject noise into the sampling process. The AD676 is tested with no CLK cycles during the sampling period. The BUSY signal can be used to prevent the clock from running during acquisition, as illustrated in Figure 3. In this circuit BUSY is used to reset the circuitry which divides the system clock down to provide the AD676 CLK. This serves to interrupt the clock until after the input signal has been ac- quired, which has occurred when BUSY goes HIGH. When the conversion is completed and BUSY goes LOW, the circuit in Figure 3 truncates the 17th CLK pulse width which is tolerable because only its rising edge is critical. 5 2 10 7 1 7 12 9 4 11 12.288MHz SYSTEM CLOCK CLK 74HC175 2D 1Q CLR 3D 2Q 3Q 1D BUSY CLK AD676 9 SAMPLE 2 8 9 12 6 13 1 1QD 74HC393 1CLR 2CLR 2QD 2QC 1CLK 2CLK Figure 3. Figure 3 also illustrates the use of a counter (74HC393) to de- rive the AD676 SAMPLE command from the system clock when a continuous convert mode is desirable. Pin 9 (2QC) pro- vides a 96 kHz sample rate for the AD676 when used with a 12.288 MHz system clock. Alternately, Pin 8 (2QD) could be used for a 48 kHz rate. If a continuous clock is used, then the user must avoid CLK edges at the instant of disconnecting VIN which occurs at the falling edge of SAMPLE (see tSC specification). The duty cycle of CLK may vary, but both the HIGH (tCH) and LOW (tCL ) phases must conform to those shown in the timing specifica- tions. The internal comparator makes its decisions on the rising edge of CLK. To avoid a negative edge transition disturbing the comparator’s settling, tCL should be at least half the value of tCLK. To also avoid transitions disturbing the internal comparator’s settling, it is not recommended that the SAMPLE pin change state toward the end of a CLK cycle. During a conversion, internal dc error terms such as comparator voltage offset are sampled, stored on internal capacitors and used to correct for their corresponding errors when needed. Be- cause these voltages are stored on capacitors, they are subject to leakage decay and so require refreshing. For this reason there is a maximum conversion time tC (1000 µs). From the time SAMPLE goes HIGH to the completion of the 17th CLK pulse, no more than 1000 µs should elapse for specified performance. However, there is no restriction to the maximum time between conversions. Output coding for the AD676 is twos complement, as shown in Table I. By inverting the MSB, the coding can be converted to offset binary. The AD676 is designed to limit output coding in the event of out-of-range inputs. Table I. Output Coding VIN Output Code >Full Scale 011 . . . 11 Full Scale 011 . . . 11 Full Scale – 1 LSB 011 . . . 10 Midscale + 1 LSB 000 . . . 01 Midscale 000 . . . 00 Midscale – 1 LSB 111 . . . 11 –Full Scale + 1 LSB 100 . . . 01 –Full Scale 100 . . . 00 <–Full Scale 100 . . . 00 |
Numéro de pièce similaire - AD676BD |
|
Description similaire - AD676BD |
|
|
Lien URL |
Politique de confidentialité |
ALLDATASHEET.FR |
ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |