Moteur de recherche de fiches techniques de composants électroniques |
|
TSB41BA3DPFP Fiches technique(PDF) 7 Page - Texas Instruments |
|
|
TSB41BA3DPFP Fiches technique(HTML) 7 Page - Texas Instruments |
7 / 59 page TSB41BA3D www.ti.com ............................................................................................................................................... SLLS959A – DECEMBER 2008 – REVISED MARCH 2009 Table 1. Terminal Functions TERMINAL I/O DESCRIPTION PFP NAME TYPE NO. AGND Supply 21, 40, – Analog circuit ground terminals. These terminals must be tied together to the 43, 50, low-impedance circuit board ground plane. 61, 62 AVDD Supply 24, 39, – Analog circuit power terminals. A combination of high-frequency decoupling capacitors near 44, 51, each terminal is suggested, such as paralleled 0.1 µF and 0.001 µF. Lower frequency 57, 63 10- µF filtering capacitors are also recommended. These supply terminals are separated from the PLLVDD-CORE, PLLVDD-3.3, DVDD-CORE, and DVDD-3.3 terminals internal to the device to provide noise isolation. The PLLVDD-3.3, AVDD, and DVDD-3.3 terminals must be tied together with a low dc impedance connection on the circuit board. BMODE CMOS 74 I Beta-mode input. This terminal determines the PHY-link interface connection protocol. When logic-high (asserted), the PHY-link interface complies with the 1394b-2002 B PHY-link interface. When logic-low (deasserted), the PHY-link interface complies with the legacy 1394a-2000 standard. When using an LLC such as the 1394b-2002 TSB82AA2, this terminal must be pulled high. When using an LLC such as the 1394a-2000 TSB12LV26, this terminal must be tied low. NOTE: The PHY-link interface cannot be changed between the different protocols during operation. CPS CMOS 34 I Cable-power status input. This terminal is normally connected to cable power through a 400-k Ω resistor. This circuit drives an internal comparator that detects the presence of cable power. This transition from cable power sensed to cable power not sensed can be used to generate an interrupt to the LLC. CTL0 CMOS 9 I/O Control I/Os. These bidirectional signals control communication between the TSB41BA3D CTL1 10 and the LLC. Bus holders are built into these terminals. D0–D7 CMOS 11, 12, I/O Data I/Os. These are bidirectional data signals between the TSB82BA3 and the LLC. Bus 13, 15, holders are built into these terminals. 16, 17, If power management control (PMC) is selected using LCLK_PMC, then some of these 19, 20 terminals can be used for PMC. See the LCLK_PMC terminal description for more information. DGND Supply 4, 14, Digital circuit ground terminals. These terminals must be tied together to the low-impedance 38, 64, circuit board ground plane. 72, 76 DVDD-CORE Supply 8, 37, – Digital core circuit power terminals. A combination of high-frequency decoupling capacitors 65, 71 near each terminal is suggested, such as paralleled 0.1 µF and 0.001 µF. An additional 1-µF capacitor is required for voltage regulation. These supply terminals are separated from the DVDD-3.3, PLLVDD-CORE, PLLVDD-3.3, and AVDD terminals internal to the device to provide noise isolation. DVDD-3.3 Supply 6, 18, – Digital 3.3-V circuit power terminals. A combination of high-frequency decoupling capacitors 69, 70 near each terminal is suggested, such as paralleled 0.1 µF and 0.001 µF. Lower-frequency 10-µF filtering capacitors are also recommended. The DVDD-3.3 terminals must be tied together at a low-impedance point on the circuit board. These supply terminals are separated from the PLLVDD-CORE, PLLVDD-3.3, DVDD-CORE, and AVDD terminals internal to the device to provide noise isolation. The PLLVDD-3.3, AVDD, and DVDD-3.3 terminals must be tied together with a low dc impedance connection on the circuit board. Copyright © 2008–2009, Texas Instruments Incorporated Submit Documentation Feedback 7 Product Folder Link(s): TSB41BA3D |
Numéro de pièce similaire - TSB41BA3DPFP |
|
Description similaire - TSB41BA3DPFP |
|
|
Lien URL |
Politique de confidentialité |
ALLDATASHEET.FR |
ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |