2 / 2 page © 2003 System Sensor. The company reserves the right to change product specifications without notice. A05-0349-001•7/03•#1115 Physical Specifications Operating Temperature Range 14°F–122°F (–10°C to 50°C) Operating Humidity Range 0 to 95% RH non-condensing Input Terminals 14–22 AWG Dimensions Height: 4.5 inches (114 mm) Width: 4.0 inches (101 mm) Depth: 1.25 inches (32 mm) Weight 8 oz. (225 grams) Mounting 4-inch square back box Electrical Specifications Operating Voltage Nominal: 12/24 V Min.: 8.5 V power limited Max.: 30 V power limited Maximum Ripple Voltage 30% of applied voltage (peak to peak) Maximum Standby Current 30 mA Maximum Alarm Current 90 mA Maximum Maintenance Current 53 mA Alarm Contact Ratings 0.5 A @ 36VDC, Resistive Maintenance Contact Ratings 2 A @ 30VDC, Resistive Loop test/maintenance module shall be a System Sensor i3 series model num- ber 2W-MOD2, listed to Underwriters Laboratories UL 864 for Control Units for Fire Protection Signaling Systems. The module shall include provisions for mounting to 4″-inch square back boxes. Wiring connections shall be made by means of SEMS screws. The module shall provide three LED indicators which will blink or illuminate to indicate com- munication status, maintenance alert, alarm or freeze trouble conditions, and EZ Walk loop test mode. The module shall allow communication to 2-wire i3 detectors with any UL listed fire alarm control panel. The 2W-MOD2 shall offer provisions for Style D wiring on IDC loops, and shall provide a loop testing capability to verify the initiating loop wir- ing. Architect/Engineer Specifications Model Description 2W-MOD2 2-wire loop test/maintenance module for 2-wire i3 series standard, sounder, and Form C relay smoke detectors Ordering Information LED Modes LED Color Status Condition Green LED On Power on. Detectors on loop do not have communication capability. Blinking 1 sec. on / 1 sec. off Power on. Detectors on loop are communicating normally. Off Power not applied or module not in operation. Red LED On Detector on loop in alarm. Blinking 1 sec. on / 1 sec. off One or more detector on loop is in need of maintenance or is in freeze trouble. Yellow LED On Loop wiring fault exists. Blinking 0.5 sec. on / 0.5 sec. off EZ Walk test mode. Power Up Sequence for LED Indication Condition Duration Initial LED status indication 2 minutes EZ Walk test available 6 minutes after reset System Sensor Sales and Service System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800/SENSOR2 Fx: 630/377-6495 www.systemsensor.com System Sensor Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor Europe Ph: 44.1403.276500 Fx: 44.1403.276501 System Sensor in China Ph: 86.29.8832.0119 Fx: 86.29.8832.5110 System Sensor in Singapore Ph: 65.6273.2230 Fx: 65.6273.2610 System Sensor – Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor – Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sensor – India Ph: 91.124.637.1770 x.2700 Fx: 91.124.637.3118 System Sensor – Russia Ph: 70.95.937.7982 Fx: 70.95.937.7983 |
Numéro de pièce similaire - 2W-MOD2 |
|
Description similaire - 2W-MOD2 |
|
|
Lien URL |
Politique de confidentialité |
ALLDATASHEET.FR |
ALLDATASHEET vous a-t-il été utile ? [ DONATE ] |
À propos de Alldatasheet | Publicité | Contactez-nous | Politique de confidentialité | Echange de liens | Fabricants All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |